Industry News

Relay main product technical parameters

Refers to the minimum current that the relay can generate the draw action. In normal use, the given current must be slightly greater than the draw current for the relay to be stable To work. The working voltage added to the coil, generally do not exceed 1.5 times of the rated working voltage, otherwise it will produce a large current and burn the coil.

Relays control how relays form self-locking interlocking circuits

Self-locking and interlocking are achieved by auxiliary contacts of relays. First of all, you need to understand what is called self-locking and what is called interlocking. Self-locking is to short off the button switch of the contactor coil loop with your own contacts, and make the coil loop open continuously after the button switch is released, which is self-locking.

Application status and development trend of voltage transformer

The rise and development of intelligent power grid technology has put forward new requirements for voltage and current sensors in power system. Miniaturized non-contact sensors will be the mainstream and need. This paper summarizes the application status of traditional electromagnetic voltage transformers and capacitive voltage transformers, and points out their limitations. On the basis of introducing the D-dot measurement principle in high voltage pulse electrical measurement, an electronic voltage transformer based on self-integrating D-dot sensor is proposed, and it is pointed out that it will be the mainstream trend of voltage signal measurement in power system.

The concept of smart meters

As an intelligent product developed by new technology, smart electricity meter can complete the contact function between users and smart grid. It not only has the function of human-computer interaction, but also has the basic function of electricity energy measurement, information transmission and remote status monitoring.

Saturation of the current transformer

As we mentioned earlier, errors of the CT are mainly caused by the field current Ie. Due to the large excitation impedance in normal operation, Ie is small, so that this error can be ignored. However, when the CT is saturated, the more serious the saturation degree is, the smaller the excitation impedance is and the greatly increased excitation current makes the error of the CT multiply and affects the correct operation of the protection.

Oswell E-Group Ltd. Attend Enlit Europe 2022 today

This exhibition will focus on:Power plant products and equipment systems: power devices, high voltage switches, transmission, distribution network, transformers, current transformers, voltage transformers, power capacitors, high voltage cabinets, monitors, electrical engineering, power supply and accessories, wires and cables, insulation materials, measurement and electronic equipment systems, etc

What is a Smart Meter?

​Smart meter is a metering device that can measure electricity remotely through RS485 data transmission and terminal computer software management. Free automatic power off, timed power off, student apartment malignant load identification and other functions.

Potential Transformer Construction and working

Potential transformer or PT can have the same construction as any normal transformer. It has primary & secondary winding. The number of turns in primary windings is greater than the number of turns in the secondary winding because it is a step-down transformer.

Usage of current transformers

A transformer ​is a device that converts voltage or current proportionally. The function of the transformer is to convert high voltage or high current into standard low voltage (100V) or standard low current (5A or 1A, both referring to the rated value), so as to achieve the standardization and miniaturization of measuring instruments, protection equipment and automatic control equipment.

Three basic types of current transformer

Wound Current Transformer – The transformers primary winding is physically connected in series with the conductor that carries the measured current flowing in the circuit. The magnitude of the secondary current is dependent on the turns ratio of the transformer.