90A Magnetic Latching Relay For Smart Meter Load Switching

  • 90A Magnetic Latching Relay For Smart Meter Load Switching
  • 90A Magnetic Latching Relay For Smart Meter Load Switching
  • 90A Magnetic Latching Relay For Smart Meter Load Switching
90A Magnetic Latching Relay For Smart Meter Load Switching

This 90A magnetic latching relay provides high current switching for smart meters, prepaid metering products and load control systems. Its bistable structure helps reduce power consumption while maintaining stable contact status after switching.

90A Magnetic Latching Relay For Smart Meter Load Switching technical overview

90A Magnetic Latching Relay For Smart Meter Load Switching is organized for buyers comparing Latching Relay for smart energy meters, current measurement, EV charging, meter cases, LCD modules, relays, terminals, and power monitoring projects. Review the existing product details and images below, then compare related Eoswell products for compatible sourcing options.

SH617 -90A

AMBIENT TEMP.

-40℃~+70℃

VIBRATION RESISTANCE

10-55Hz, 0.5mm 

(Double   Amplitude)

SHOCK RESISTANCE

98m/s² 11ms

RELATIVE HUMIDITY

45%~85%

INSULATION RESISTANCE

1000 MΩ(500VDC)

DIELECTRIC 

STRENGTH

BETWEEN CONTACTS

2000  VAC  50/60Hz     (1 minute)

BETWEEN CONTACT & COIL

4000  VAC    50/60Hz   (1 minute)

ELECTRICAL LIFE

≥1ⅹ104OPS

MECHANICAL LIFE

≥1ⅹ106OPS

DIMENSIONS (mm)

38×30×16.5

PICK-UP TIME (At rated Voltage):   ≤20ms

RELEASE TIME (At rated Voltage):   ≤20ms

BOUNCE TIME:  ≤2ms

CONSTRUCTION:  DUST protected 

90A latching relay

Standard products (gb, iec, en, ul) that meet the specifications of various countries and have obtained certification for overseas specifications


Electrical life (ac-3): 1.5 million times (e02-e3 type)


The double contact of the auxiliary contact improves the reliability of the contact (e02-n12 type)


Corresponding to different wiring needs, provide direct wiring corresponding type and 0-type terminal corresponding type in two ways (sc-e02-sc-e7)


Highly reliable operation (e5-n16) is realized through the installation of ic supermagnet (ac input, dc excitation method)


Will not cause coil burnout and chaotic operation due to voltage fluctuations, and prevent joint welding and damage


The power supply has a regular rated voltage when it passes through, and it can be used normally even if the voltage drops to 65% of the rated voltage when the main connector is in contact.


Prevent under-voltage starting of the motor


Related Products 100A Magnetic Latching Relay For Smart Meter Load Switching SH617 90A Magnetic Latching Relay For Smart Meter Load Switching SH618 120A Magnetic Latching Relay For Smart Meter Load Switching

Relay Production
Relay Production
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right