Cable Type Split Core Current Transformer
Cable Type Split Core Current Transformer is designed for convenient current measurement in existing electrical systems. It supports retrofit installation, energy metering and power monitoring projects where fast and reliable sensing is required.
Cable Type Split Core Current Transformer technical overview
Cable Type Split Core Current Transformer is organized for buyers comparing Split-Core CT for smart energy meters, current measurement, EV charging, meter cases, LCD modules, relays, terminals, and power monitoring projects. Review the existing product details and images below, then compare related Eoswell products for compatible sourcing options.
SDK25
Model No. | Rated Current | Turns Ratio | Output Current | Accuracy | Load |
SDK25 | 20A~300A | 1:100 1:200 1:1000 Or on request | 150mA/50mA/20mA or on request | Class 0.2 Class 0.5 | ≤ 4Ω (mA output) |
Working Temp.: -40℃~+70℃ (ABS Housing) -40℃~+80℃ (PC Housing) Secondary Cable: 2.0m Primary Busbar is available as per requirement | Insulation Voltage(Hi-pot): 4kV/1min BIL: 10kV/10times Insulation Resistance: DC500V/500MΩ min | ||||

SDK30
Model No. | Rated Current | Turns Ratio | Output Current | Accuracy | Load |
SDK30 | 10~600A | 1:100 1:200 1:1000, or on request | 50mA/1A/5A or on request | Class 0.1 Class 0.2 Class 0.5 | ≤ 4Ω (mA output) ≤0.1Ω (1A output) ≤2.5VA (5A output) |
Working Temp.: -40℃~+60℃ (ABS Housing) | |||||

SDK40
Model No. | Rated Current | Turns Ratio | Output Current | Accuracy | Load |
SDK40 | 10A~400A | 1:100, 1:200 1:1000, --- 1:50000 | 0.1A/1A/2A/5A or on request | 0.1Class 0.2Class 0.5Class | ≤ 4Ω (mA output) ≤0.1Ω (1A output) ≤2.5VA (5A output) |
Working Temp.: -40℃ ~ +60℃ (ABS Housing) Secondary Cable: 2.5m Primary Busbar is available as per requirement | Insulation Voltage(Hi-pot): 4kV/1min BIL: 1.2μs/50μs 10kV/10times Insulation Resistance: DC500V/500MΩ min | ||||

SDK55
Model No. | Rated Current | Turns Ratio | Output Current | Accuracy | Load |
SDK55 | 50A~1000A | 1:100, 1:200 1:1000, --- 1:50000 | 1A/2A/5A or on request | 0.1Class 0.2Class 0.5Class | ≤ 4Ω (mA output) ≤0.1Ω(1A output) 2.5VA, 5VA, 10VA (5A output) |
Working Temp.: -40℃~+60℃ (ABS Housing) -40℃~+80℃ (PC Housing) Secondary Cable: 2.5m Primary Busbar is available as per requirement | Insulation Voltage(Hi-pot): 4kV/1min BIL: 10kV/10times Insulation Resistance: DC500V/500MΩ min | ||||