Cable Type Split Core Current Transformer is organized for buyers comparing Split-Core CT for smart energy meters, current measurement, EV charging, meter cases, LCD modules, relays, terminals, and power monitoring projects. Review the existing product details and images below, then compare related Eoswell products for compatible sourcing options.

SDK25

Model No.

Rated Current

Turns   Ratio

Output Current

Accuracy

Load

SDK25

20A~300A

1:100

1:200

1:1000

Or on request

150mA/50mA/20mA

or on   request

Class 0.2

Class 0.5

≤ 4Ω (mA output)

Working Temp.: -40℃~+70℃ (ABS Housing)

              -40℃~+80℃ (PC Housing)

Secondary Cable: 2.0m

Primary Busbar is available as per requirement

Insulation Voltage(Hi-pot): 4kV/1min    

BIL: 10kV/10times

Insulation Resistance: DC500V/500MΩ min

split core current transformer



SDK30

Model No.

Rated Current

Turns   Ratio

Output Current

Accuracy

Load

SDK30

10~600A

1:100

1:200

1:1000,

or on request

50mA/1A/5A

or on request

Class 0.1

Class 0.2

Class 0.5

≤ 4Ω (mA output)

≤0.1Ω (1A output)

≤2.5VA (5A output)

Working Temp.: -40~+60 (ABS Housing)

miniature split core CT


SDK40

Model No.

Rated Current

Turns   Ratio

Output Current

Accuracy

Load

SDK40

10A~400A

1:100, 1:200

1:1000, ---

1:50000

0.1A/1A/2A/5A

or on request

0.1Class

0.2Class

0.5Class

≤ 4Ω (mA output)

≤0.1Ω (1A output)

≤2.5VA (5A output)

Working Temp.: -40℃ ~ +60℃ (ABS Housing)

Secondary Cable: 2.5m

Primary Busbar is available as per requirement

Insulation Voltage(Hi-pot): 4kV/1min    

BIL: 1.2μs/50μs  10kV/10times

Insulation Resistance: DC500V/500MΩ min

retrofit current transformer


SDK55

Model No.

Rated Current

Turns   Ratio

Output Current

Accuracy

Load

SDK55

50A~1000A

1:100, 1:200

1:1000, ---

1:50000

1A/2A/5A

or on request

0.1Class

0.2Class

0.5Class

≤ 4Ω (mA output)

≤0.1Ω(1A output)

2.5VA, 5VA, 10VA (5A   output)

Working Temp.: -40℃~+60℃ (ABS Housing)

              -40℃~+80℃ (PC Housing)

Secondary Cable: 2.5m

Primary Busbar is available as per requirement

Insulation Voltage(Hi-pot): 4kV/1min    

BIL: 10kV/10times

Insulation Resistance: DC500V/500MΩ min

split core current transformer

Related Products Miniature Type Split Core Current Transformer SDK16-104-01 120A Miniature Split Core Current Transformer SDK10-75-01 75A Miniature Split Core Current Transformer

Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right